Description
The pump body is bolted straight onto the motor housing and the rotor runs on the motor shaft, so the whole unit is one integrated motor-driven block. As the rotor turns, the vanes slide in their slots and gas is drawn in at the inlet port and pushed out at the outlet port. Speed is adjustable across the range,which is what lets the controller track the dispenser.

Technical Specifications
| Parameter | Value |
| Ex marking | Ex db IIA T3 Gb |
| Protection grade | IP55 |
| Ambient temperature | −20 °C to +50 °C |
| Ambient pressure | 80 kPa to 106 kPa |
| Max. flow rate | 65 L/min |
| Max. vacuum | 0.05 MPa |
| Voltage | 36 V DC |
| Motor power | 45 W |
| Noise | < 60 dB |
| Weight | 5 kg |
| Gas port thread | BSP F 1/2″ female |
Where It Can Be Installed
✅ Altitude not above 1 000 m
✅ Ambient air temperature from −20 °C up to +50 °C, following the season
✅ Maximum monthly average relative humidity 90 %, with that month’s average minimum temperature not above 25 °C
✅ Hazardous areas Zone 1 and Zone 2 with IIA, T3 gas or vapor mixtures
Installation follows GB/T 3836.15-2017, inspection and maintenance GB/T 3836.16-2017, and repair and overhaul GB 3836.13-2013. Final values are confirmed per order — contact our engineering team for the drawing, the certificate set and the spare-parts list.