PRM Variable Frequency Vapor Recovery Pump
The PRM Variable Frequency Vapor Recovery Pump is designed for gasoline fuel dispensers and petrol station vapor recovery systems. With a 60 L/min vapor recovery capacity and low-pressure vacuum motor design, it helps equipment manufacturers and station operators build a more responsive vapor recovery solution for daily refueling operations.
PRM supplies vapor recovery equipment and fuel dispenser components for petrol stations, including nozzles, hoses, breakaways, separators, vacuum pumps and vapor recovery units. Contact PRM for model matching, electrical configuration and OEM supply requirements.
Product Introduction
The Variable Frequency Vapor Recovery Pump is not a gasoline transfer pump. It is a vacuum pump used to move gasoline vapor and air mixture through a compatible vapor recovery circuit during vehicle refueling.
Its variable-frequency operating concept allows the pump speed to be matched with the actual vapor recovery demand of the dispenser. Compared with a fixed-speed operating approach, this supports more flexible system control when dispensing conditions change.
The pump is intended for integration with compatible fuel dispensers, vapor recovery hoses, nozzles, separators and electrical control systems. Final selection should be based on dispenser layout, fuel type, vapor line configuration and local compliance requirements.
Product Parameters
|
Item |
Specification |
|
Brand |
PRM |
|
Product type |
Variable Frequency Vapor Recovery Pump |
|
Application |
Gasoline fuel dispenser / petrol station |
|
Pump function |
Vapor-air mixture recovery |
|
Drive type |
Vacuum motor with variable-frequency control |
|
Pressure class |
Low pressure |
|
Listed vapor recovery capacity |
60 L/min |
|
Suitable system |
Fuel dispenser vapor recovery system |
|
Fuel application |
Gasoline vapor recovery |
|
OEM support |
Available upon project confirmation |
Key Features
Variable-frequency operating control
The PRM Variable Frequency Vapor Recovery Pump is designed to work with variable-speed control, allowing the vapor recovery function to respond more closely to dispenser operating conditions.
60 L/min vapor recovery capacity
The listed 60 L/min capacity makes this pump suitable for matching with compatible gasoline dispenser vapor recovery systems.
Low-pressure vacuum design
The pump is designed for vapor recovery circulation rather than liquid fuel transfer. It helps create the vacuum needed to collect fuel vapor from the dispensing process.
Designed for fuel dispenser integration
The Variable Frequency Vapor Recovery Pump can be matched with compatible vapor recovery nozzles, coaxial hoses, separators and dispenser control systems.
Support for system optimization
By selecting the correct pump configuration and frequency-control settings, fuel dispenser manufacturers can tailor vapor recovery performance to their equipment design.
Applications
The PRM Variable Frequency Vapor Recovery Pump is suitable for:
Product Details
Vacuum motor section
The motor provides the vacuum force required to move vapor-air mixture through the recovery circuit. Electrical specifications must match the final dispenser design.
Variable-frequency control connection
The frequency-control interface should be selected according to the control method used by the dispenser. Confirm input signal, voltage and operating logic before purchase.
Vapor inlet and outlet ports
The pump connects to compatible vapor recovery piping. Confirm fitting size, hose type and installation direction before production.
Pump housing and mounting
The final housing size and mounting arrangement should be confirmed with PRM according to the available installation space inside the dispenser.
Installation and Maintenance
Install the Variable Frequency Vapor Recovery Pump only in a compatible gasoline dispenser or vapor recovery assembly. Ensure that all electrical work, grounding, piping and commissioning are completed by qualified personnel.
Before start-up, check the vapor hose routing, connection tightness, control wiring and dispenser signal. During operation, inspect the pump regularly for abnormal noise, vibration, leakage or damaged connections. Stop the equipment and investigate immediately if the vapor recovery system does not respond as expected.
Quality and Supply Support
PRM can support project-based supply for fuel dispenser vapor recovery systems. Before placing an order, provide the dispenser model, required vapor recovery capacity, available installation space, control signal, voltage, local standards and requested packaging method.
For export projects, request the final product drawing, nameplate photo, technical data sheet, inspection requirement and applicable certification documents before mass production.
FAQ
Is this pump used to transfer gasoline?
No. It is designed to recover gasoline vapor and air mixture in a compatible vapor recovery system.
What is the listed capacity?
The publicly listed capacity is 60 L/min. Actual system performance depends on dispenser configuration and control settings.
Can it be installed on an existing fuel dispenser?
Compatibility must be confirmed based on mounting dimensions, electrical control, vapor piping and required recovery performance.
Does the pump include variable-frequency control?
It is marketed as a variable-frequency vapor recovery pump. Confirm whether the inverter, controller and wiring harness are included with the requested configuration.
Can PRM provide OEM service?
Yes. OEM and project-specific configuration can be discussed based on your dispenser design and destination-market requirements.