Description
The coaxial vapor recovery hose is primarily designed for transporting fuel and recovering gasoline vapor in Stage II vapor recovery systems at gas stations.
Both ends of the hose are equipped with durable stainless steel swivel joints, allowing flexible movement during vehicle refueling. The electrical resistance between both ends of the hose is no greater than 5 Ω. During winter operation, static electricity generated during use can be quickly conducted to the grounding terminal of the fuel dispenser, helping prevent electrostatic sparks.
Product Standards
✅ HG/T 3037-2008: Rubber and Plastics Hoses and Hose Assemblies for Metering and Dispensing Fuels
✅ GB/T 5563-2013: Rubber and Plastics Hoses and Hose Assemblies – Hydrostatic Testing
✅ GB 7542-2003: Rubber Hose for Railway Locomotive Brakes
Enterprise Standard: Q/PRM004-2014
Structure Drawing of Hose
| Name of Parameter | Technical Indicator |
| Connecting Thread | M34x 1.5 |
| Electrical Conductivity | ≤5Ω |
| Air Tightness | 0.5Mpa without leakage |
| Tensile Test | 2000N tensile force holding 30s without separation |
| Hose Length | 4.5m/6m |
| Working Temperature | 40~+60°C |